Technical specifications
Rated permanent current Iu
250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
No
Position of connection for main current circuit
Front side
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
100 - 1000A
DIN rail (top hat rail) mounting optional
Yes
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
0
Type of control element
Toggle
Suitable for DIN rail (top hat rail) mounting
No
Motor drive integrated
No
Number of poles
4
Adjustment range short-term delayed short-circuit release
100 - 1000A
Number of auxiliary contacts as normally open contact
0
Degree of protection (IP)
IP20
Overload release current setting
40.0 - 100A
With switched-off indicator
No
Rated voltage
240 - 600V
With integrated under voltage release
No
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA080266R1 | XT4L 250 EKIP E-LSIG In100A 4p FF UL/CSA

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Position of connection for main current circuit
Front side
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
100 .. 1000A
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Number of auxiliary contacts as change-over contact
0
Type of control element
Toggle
Suitable for DIN rail (top hat rail) mounting
Motor drive integrated
Number of poles
4
Adjustment range short-term delayed short-circuit release
100 .. 1000A
Number of auxiliary contacts as normally open contact
0
Degree of protection (IP)
IP20
Overload release current setting
40.0 .. 100A
With switched-off indicator
Rated voltage
240 .. 600V
With integrated under voltage release
Motor drive optional