1SDA080251R1 | XT4H 250 EKIP E-LSIG In225A 4p FF UL/CSA
Code: 1985921
Sign in or create an account for lower prices and other benefits
Code: 1985921
Sign in or create an account for lower prices and other benefits
Adjustment range undelayed short-circuit release
225 - 2250A
DIN rail (top hat rail) mounting optional
Yes
Adjustment range short-term delayed short-circuit release
225 - 2250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated voltage
240 - 600V
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Overload release current setting
90.0 - 225A
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
No
Position of connection for main current circuit
Front side
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Yes
Rated permanent current Iu
250A
Device construction
Built-in device fixed built-in technique
Complete device with protection unit
Yes
Motor drive integrated
No
With switched-off indicator
No
Degree of protection (IP)
IP20
Type of control element
Toggle
With integrated under voltage release
No
Zagreb:
0 pcs
Zadar:
0 pcs
1SDA080251R1 | XT4H 250 EKIP E-LSIG In225A 4p FF UL/CSA
Code
1985921
Catalog number
XT4S250TMA3
Type
Power circuit-breaker for trafo/generator/installation protection
Manufacturer
ABBSerie
-
2.276,02 €
Total stock:
0 PCS
Adjustment range undelayed short-circuit release
225 .. 2250A
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
225 .. 2250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated voltage
240 .. 600V
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Overload release current setting
90.0 .. 225A
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
Position of connection for main current circuit
Front side
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Rated permanent current Iu
250A
Device construction
Built-in device fixed built-in technique
Complete device with protection unit
Motor drive integrated
With switched-off indicator
Degree of protection (IP)
IP20
Type of control element
Toggle
With integrated under voltage release