1SDA080231R1 | XT4S 250 EKIP E-LSIG In=40A 4p FF UL/CSA
Code: 1985901
Sign in or create an account for lower prices and other benefits
Code: 1985901
Sign in or create an account for lower prices and other benefits
Rated permanent current Iu
250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
35kA
Rated voltage
240 - 600V
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
16.0 - 40A
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
40 - 400A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Yes
With integrated under voltage release
No
Number of poles
4
Type of control element
Toggle
Motor drive integrated
No
Complete device with protection unit
Yes
With switched-off indicator
No
Position of connection for main current circuit
Front side
Degree of protection (IP)
IP20
Motor drive optional
Yes
Device construction
Built-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release
40 - 400A
Zagreb:
0 pcs
Zadar:
0 pcs
1SDA080231R1 | XT4S 250 EKIP E-LSIG In=40A 4p FF UL/CSA
Code
1985901
Catalog number
XT4S250TMA3
Type
Power circuit-breaker for trafo/generator/installation protection
Manufacturer
ABBSerie
-
1.229,27 €
Total stock:
0 PCS
Rated permanent current Iu
250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
35kA
Rated voltage
240 .. 600V
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
16.0 .. 40A
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
40 .. 400A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
With integrated under voltage release
Number of poles
4
Type of control element
Toggle
Motor drive integrated
Complete device with protection unit
With switched-off indicator
Position of connection for main current circuit
Front side
Degree of protection (IP)
IP20
Motor drive optional
Device construction
Built-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release
40 .. 400A