Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Interlockable
Yes
Type of control element
Push button
Version as main switch
Yes
Version as emergency stop installation
No
Number of switches
0
Version as safety switch
No
Rated permanent current at AC-21, 400 V
2000A
Rated permanent current at AC-23, 400 V
2000A
Motor drive integrated
No
Rated short-time withstand current lcw
65kA
Motor drive optional
Yes
Version as maintenance-/service switch
No
Voltage release optional
Yes
Suitable for front mounting centre
No
Number of poles
3
Suitable for intermediate mounting
No
Max. rated operation voltage Ue AC
600V
Type of electrical connection of main circuit
Bolt connection
Degree of protection (IP), front side
IP30
Degree of protection (NEMA)
Other
Suitable for front mounting 4-hole
No
Colour control element
Other
Suitable for distribution board installation
Yes
Rated permanent current Iu
2000A
Version as reversing switch
No
Suitable for floor mounting
No
Rated operating voltage
600 - 600V
Device construction
Built-in device fixed built-in technique
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA079566R1 | E2.2S-A/MS 2000 3p F HR

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Interlockable
Type of control element
Push button
Version as main switch
Version as emergency stop installation
Number of switches
0
Version as safety switch
Rated permanent current at AC-21, 400 V
2000A
Rated permanent current at AC-23, 400 V
2000A
Motor drive integrated
Rated short-time withstand current lcw
65kA
Motor drive optional
Version as maintenance-/service switch
Voltage release optional
Suitable for front mounting centre
Number of poles
3
Suitable for intermediate mounting
Max. rated operation voltage Ue AC
600V
Type of electrical connection of main circuit
Bolt connection
Degree of protection (IP), front side
IP30
Degree of protection (NEMA)
Other
Suitable for front mounting 4-hole
Colour control element
Other
Suitable for distribution board installation
Rated permanent current Iu
2000A
Version as reversing switch
Suitable for floor mounting
Rated operating voltage
600 .. 600V
Device construction
Built-in device fixed built-in technique
From same serie