Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Number of switches
0
Rated operation power at AC-3, 400 V
-kW
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Interlockable
Yes
Version as main switch
Yes
Version as reversing switch
No
Max. rated operation voltage Ue AC
600V
Version as emergency stop installation
No
Version as safety switch
No
Rated operating voltage
600 - 600V
Rated permanent current at AC-21, 400 V
1200A
Number of poles
3
Motor drive integrated
No
Motor drive optional
Yes
Version as maintenance-/service switch
No
Rated permanent current Iu
1200A
Rated short-time withstand current lcw
42kA
Rated permanent current at AC-23, 400 V
1200A
Suitable for front mounting 4-hole
No
Suitable for floor mounting
No
Device construction
Built-in device fixed built-in technique
Suitable for front mounting centre
No
Voltage release optional
Yes
Suitable for distribution board installation
Yes
Type of electrical connection of main circuit
Bolt connection
Colour control element
Other
Degree of protection (NEMA)
Other
Type of control element
Push button
Degree of protection (IP), front side
IP30
Suitable for intermediate mounting
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA079549R1 | E1.2B-A/MS 1200 3p F F

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Number of switches
0
Rated operation power at AC-3, 400 V
-kW
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Interlockable
Version as main switch
Version as reversing switch
Max. rated operation voltage Ue AC
600V
Version as emergency stop installation
Version as safety switch
Rated operating voltage
600 .. 600V
Rated permanent current at AC-21, 400 V
1200A
Number of poles
3
Motor drive integrated
Motor drive optional
Version as maintenance-/service switch
Rated permanent current Iu
1200A
Rated short-time withstand current lcw
42kA
Rated permanent current at AC-23, 400 V
1200A
Suitable for front mounting 4-hole
Suitable for floor mounting
Device construction
Built-in device fixed built-in technique
Suitable for front mounting centre
Voltage release optional
Suitable for distribution board installation
Type of electrical connection of main circuit
Bolt connection
Colour control element
Other
Degree of protection (NEMA)
Other
Type of control element
Push button
Degree of protection (IP), front side
IP30
Suitable for intermediate mounting
From same serie