Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
600 - 600V
Overload release current setting
2000.0 - 5000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
3000.0 - 50000A
Rated permanent current Iu
5000A
With under voltage release
No
Type of electrical connection of main circuit
Bolt connection
Type of control element
Push button
Adjustment range undelayed short-circuit release
7500.0 - 75000A
Device construction
Built-in device fixed built-in technique
Position of connection for main current circuit
Back side
Number of poles
4
With switched-off indicator
Yes
Motor drive integrated
No
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA079387R1 | E6.2V-A/f 5000 Ekip G Hi-Tch LSIG 4p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
600 .. 600V
Overload release current setting
2000.0 .. 5000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
3000.0 .. 50000A
Rated permanent current Iu
5000A
With under voltage release
Type of electrical connection of main circuit
Bolt connection
Type of control element
Push button
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
Device construction
Built-in device fixed built-in technique
Position of connection for main current circuit
Back side
Number of poles
4
With switched-off indicator
Motor drive integrated
Complete device with protection unit
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
From same serie