Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
5000A
Rated voltage
600 - 600V
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Bolt connection
Position of connection for main current circuit
Back side
Overload release current setting
2000.0 - 5000A
Adjustment range undelayed short-circuit release
7500.0 - 75000A
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range short-term delayed short-circuit release
3000.0 - 50000A
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
No
With switched-off indicator
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA079379R1 | E6.2V-A/f 5000 Ekip Dip LSI 4p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
5000A
Rated voltage
600 .. 600V
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Bolt connection
Position of connection for main current circuit
Back side
Overload release current setting
2000.0 .. 5000A
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range short-term delayed short-circuit release
3000.0 .. 50000A
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
With switched-off indicator
Motor drive optional
Degree of protection (IP)
IP30
Complete device with protection unit
Motor drive integrated
From same serie
We use cookies to enhance your experience.