Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Overload release current setting
2000.0 - 5000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Adjustment range short-term delayed short-circuit release
3000.0 - 50000A
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
No
Adjustment range undelayed short-circuit release
7500.0 - 75000A
DIN rail (top hat rail) mounting optional
No
Rated permanent current Iu
5000A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
600 - 600V
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Type of control element
Push button
Motor drive optional
Yes
Motor drive integrated
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
From same serie
1SDA079082R1 | E6.2H-A 5000 Ekip Touch LSI 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Overload release current setting
2000.0 .. 5000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Adjustment range short-term delayed short-circuit release
3000.0 .. 50000A
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
DIN rail (top hat rail) mounting optional
Rated permanent current Iu
5000A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
600 .. 600V
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Type of control element
Push button
Motor drive optional
Motor drive integrated
Complete device with protection unit
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
From same serie