Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range short-term delayed short-circuit release
3000.0 - 50000A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
7500.0 - 75000A
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Bolt connection
Degree of protection (IP)
IP30
With switched-off indicator
Yes
Number of poles
4
Integrated earth fault protection
No
Type of control element
Push button
Rated permanent current Iu
5000A
Device construction
Built-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Motor drive optional
Yes
Complete device with protection unit
Yes
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Overload release current setting
2000.0 - 5000A
Position of connection for main current circuit
Back side
Rated voltage
600 - 600V
DIN rail (top hat rail) mounting optional
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA079025R1 | E6.2V-A 5000 Ekip Hi-Touch LSI 4p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range short-term delayed short-circuit release
3000.0 .. 50000A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Bolt connection
Degree of protection (IP)
IP30
With switched-off indicator
Number of poles
4
Integrated earth fault protection
Type of control element
Push button
Rated permanent current Iu
5000A
Device construction
Built-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Motor drive optional
Complete device with protection unit
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Overload release current setting
2000.0 .. 5000A
Position of connection for main current circuit
Back side
Rated voltage
600 .. 600V
DIN rail (top hat rail) mounting optional
From same serie