Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
4000A
With switched-off indicator
Yes
Device construction
Built-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Number of poles
4
Rated voltage
600 - 600V
Position of connection for main current circuit
Back side
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Overload release current setting
1600.0 - 4000A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA079012R1 | E6.2V-A 4000 Ekip Touch LSI 4p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
4000A
With switched-off indicator
Device construction
Built-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Number of poles
4
Rated voltage
600 .. 600V
Position of connection for main current circuit
Back side
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Motor drive optional
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Overload release current setting
1600.0 .. 4000A