Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Integrated earth fault protection
Yes
Overload release current setting
2000.0 - 5000A
Suitable for DIN rail (top hat rail) mounting
No
Rated voltage
600 - 600V
Rated permanent current Iu
5000A
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
7500.0 - 75000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Bolt connection
Adjustment range short-term delayed short-circuit release
3000.0 - 50000A
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Type of control element
Push button
Degree of protection (IP)
IP30
Position of connection for main current circuit
Back side
Motor drive optional
Yes
Complete device with protection unit
Yes
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA078904R1 | E6.2V-A 5000 Ekip G Touch LSIG 3p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Integrated earth fault protection
Overload release current setting
2000.0 .. 5000A
Suitable for DIN rail (top hat rail) mounting
Rated voltage
600 .. 600V
Rated permanent current Iu
5000A
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Bolt connection
Adjustment range short-term delayed short-circuit release
3000.0 .. 50000A
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Type of control element
Push button
Degree of protection (IP)
IP30
Position of connection for main current circuit
Back side
Motor drive optional
Complete device with protection unit
Motor drive integrated
From same serie
We use cookies to enhance your experience.