Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
4000A
Rated voltage
600 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
1600.0 - 4000A
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as change-over contact
4
With under voltage release
No
Number of poles
3
With switched-off indicator
Yes
Motor drive integrated
No
Integrated earth fault protection
No
Complete device with protection unit
Yes
Type of control element
Push button
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Device construction
Built-in device fixed built-in technique
Degree of protection (IP)
IP30
Motor drive optional
Yes
Position of connection for main current circuit
Back side
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
Code: 1985372
1SDA078829R1 | E6.2H-A 4000 Ekip Dip LSI 3p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
4000A
Rated voltage
600 .. 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
1600.0 .. 4000A
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as change-over contact
4
With under voltage release
Number of poles
3
With switched-off indicator
Motor drive integrated
Integrated earth fault protection
Complete device with protection unit
Type of control element
Push button
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Device construction
Built-in device fixed built-in technique
Degree of protection (IP)
IP30
Motor drive optional
Position of connection for main current circuit
Back side