Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
1280.0 - 3200A
Rated permanent current Iu
3200A
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Integrated earth fault protection
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Number of poles
3
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Rated voltage
600 - 600V
Type of control element
Push button
With under voltage release
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA078533R1 | E4.2V-A 3200 Ekip Touch LSIG 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
1280.0 .. 3200A
Rated permanent current Iu
3200A
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Number of poles
3
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Rated voltage
600 .. 600V
Type of control element
Push button
With under voltage release
Motor drive optional
Degree of protection (IP)
IP30
Complete device with protection unit
From same serie