Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Overload release current setting
640.0 - 1600A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Rated voltage
600 - 600V
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Type of control element
Push button
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Number of poles
3
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA078501R1 | E4.2V-A 1600 Ekip Touch LI 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Overload release current setting
640.0 .. 1600A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Rated voltage
600 .. 600V
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Motor drive integrated
Motor drive optional
Type of control element
Push button
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Number of poles
3
From same serie