Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Overload release current setting
1280.0 - 3200A
Type of electrical connection of main circuit
Bolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Number of auxiliary contacts as change-over contact
4
Rated permanent current Iu
3200A
Rated voltage
600 - 600V
With switched-off indicator
Yes
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Back side
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
No
Number of poles
3
Complete device with protection unit
Yes
Motor drive integrated
No
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Type of control element
Push button
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA078008R1 | E4.2S-A 3200 Ekip Dip LI 3p FVR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Overload release current setting
1280.0 .. 3200A
Type of electrical connection of main circuit
Bolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Number of auxiliary contacts as change-over contact
4
Rated permanent current Iu
3200A
Rated voltage
600 .. 600V
With switched-off indicator
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Back side
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
Number of poles
3
Complete device with protection unit
Motor drive integrated
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Type of control element
Push button
From same serie
We use cookies to enhance your experience.