Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
600 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Overload release current setting
1000.0 - 2500A
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
2500A
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Bolt connection
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device fixed built-in technique
Number of poles
3
With under voltage release
No
Complete device with protection unit
Yes
With switched-off indicator
Yes
Type of control element
Push button
Motor drive integrated
No
Degree of protection (IP)
IP30
Integrated earth fault protection
No
Motor drive optional
Yes
Position of connection for main current circuit
Back side
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA078005R1 | E4.2S-A 2500 Ekip Hi-Touch LSI 3p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
600 .. 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Overload release current setting
1000.0 .. 2500A
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
2500A
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Bolt connection
DIN rail (top hat rail) mounting optional
Device construction
Built-in device fixed built-in technique
Number of poles
3
With under voltage release
Complete device with protection unit
With switched-off indicator
Type of control element
Push button
Motor drive integrated
Degree of protection (IP)
IP30
Integrated earth fault protection
Motor drive optional
Position of connection for main current circuit
Back side