Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Integrated earth fault protection
Yes
Overload release current setting
640.0 - 1600A
Complete device with protection unit
Yes
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Type of control element
Push button
With under voltage release
No
Degree of protection (IP)
IP30
Motor drive optional
Yes
Rated voltage
600 - 600V
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077894R1 | E2.2V-A 1600 Ekip G Touch LSIG 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Integrated earth fault protection
Overload release current setting
640.0 .. 1600A
Complete device with protection unit
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Type of control element
Push button
With under voltage release
Degree of protection (IP)
IP30
Motor drive optional
Rated voltage
600 .. 600V
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
From same serie