Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1200A
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
With under voltage release
No
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Complete device with protection unit
Yes
Rated voltage
600 - 600V
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1800.0 - 18000A
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
720.0 - 12000A
Overload release current setting
480.0 - 1200A
Motor drive integrated
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Motor drive optional
Yes
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077880R1 | E2.2V-A 1200 Ekip Dip LSIG 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1200A
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
With under voltage release
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Complete device with protection unit
Rated voltage
600 .. 600V
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1800.0 .. 18000A
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
720.0 .. 12000A
Overload release current setting
480.0 .. 1200A
Motor drive integrated
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Motor drive optional
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Number of poles
4
From same serie