Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated voltage
600 - 600V
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Rated permanent current Iu
2000A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Overload release current setting
800.0 - 2000A
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Number of poles
4
Complete device with protection unit
Yes
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Type of control element
Push button
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077844R1 | E2.2S-A 2000 Ekip G Touch LSIG 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated voltage
600 .. 600V
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Rated permanent current Iu
2000A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Overload release current setting
800.0 .. 2000A
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Number of poles
4
Complete device with protection unit
Motor drive optional
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Type of control element
Push button