Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Rated voltage
600 - 600V
Integrated earth fault protection
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
640.0 - 1600A
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Motor drive integrated
No
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Type of control element
Push button
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077837R1 | E2.2S-A 1600 Ekip G Hi-Touch LSIG 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Rated voltage
600 .. 600V
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
640.0 .. 1600A
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
DIN rail (top hat rail) mounting optional
Motor drive optional
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Motor drive integrated
Degree of protection (IP)
IP30
Complete device with protection unit
Type of control element
Push button
From same serie