Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Overload release current setting
640.0 - 1600A
Rated voltage
600 - 600V
Integrated earth fault protection
Yes
Rated permanent current Iu
1600A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
With switched-off indicator
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Number of poles
4
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive optional
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077834R1 | E2.2S-A 1600 Ekip G Touch LSIG 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Overload release current setting
640.0 .. 1600A
Rated voltage
600 .. 600V
Integrated earth fault protection
Rated permanent current Iu
1600A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
With switched-off indicator
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Number of poles
4
Type of control element
Push button
Complete device with protection unit
Motor drive optional
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Degree of protection (IP)
IP30
From same serie