Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
600 - 600V
Device construction
Built-in device slide-in technique (withdrawable)
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
640.0 - 1600A
Type of control element
Push button
Motor drive integrated
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077777R1 | E2.2H-A 1600 Ekip G Hi-Touch LSIG 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
600 .. 600V
Device construction
Built-in device slide-in technique (withdrawable)
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
640.0 .. 1600A
Type of control element
Push button
Motor drive integrated
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Complete device with protection unit
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Degree of protection (IP)
IP30
From same serie