1SDA077757R1 | E2.2H-A 800 Ekip G Hi-Touch LSIG 4p WMP
Code: 1984860
Sign in or create an account for lower prices and other benefits
Sign in or create an account for lower prices and other benefits
Rated permanent current Iu
800 A
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Rated voltage
600 - 600V
Overload release current setting
320.0 - 800A
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP30
Motor drive integrated
No
Complete device with protection unit
Yes
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Number of poles
4
With switched-off indicator
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Zagreb:
0 pcs
Zadar:
0 pcs
1SDA077757R1 | E2.2H-A 800 Ekip G Hi-Touch LSIG 4p WMP
Code
1984860
Catalog number
1SDA077776R1
Type
Power circuit-breaker for trafo/generator/installation protection
Manufacturer
ABBSerie
-
1,27 €
Total stock:
0 PCS
Rated permanent current Iu
800 A
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Rated voltage
600 .. 600V
Overload release current setting
320.0 .. 800A
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP30
Motor drive integrated
Complete device with protection unit
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Number of poles
4
With switched-off indicator
Type of electrical connection of main circuit
Connection at separate chassis part