Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
600 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Rated permanent current Iu
1600A
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Integrated earth fault protection
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
640.0 - 1600A
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Type of control element
Push button
With switched-off indicator
Yes
Motor drive integrated
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077747R1 | E2.2B-A 1600 Ekip G Hi-Touch LSIG 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
600 .. 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Rated permanent current Iu
1600A
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
640.0 .. 1600A
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Type of control element
Push button
With switched-off indicator
Motor drive integrated
Complete device with protection unit
Degree of protection (IP)
IP30
Motor drive optional
From same serie