Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
600 - 600V
Overload release current setting
800.0 - 2000A
Rated permanent current Iu
2000A
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Number of poles
3
With switched-off indicator
Yes
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077735R1 | E2.2V-A 2000 Ekip Hi-Touch LSI 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
600 .. 600V
Overload release current setting
800.0 .. 2000A
Rated permanent current Iu
2000A
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Number of poles
3
With switched-off indicator
Complete device with protection unit
Motor drive integrated
Motor drive optional
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
From same serie