Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
2000A
Rated voltage
600 - 600V
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
800.0 - 2000A
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
With switched-off indicator
Yes
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Yes
Motor drive integrated
No
Number of poles
3
Type of control element
Push button
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077731R1 | E2.2V-A 2000 Ekip Touch LI 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
2000A
Rated voltage
600 .. 600V
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
800.0 .. 2000A
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
With switched-off indicator
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Motor drive integrated
Number of poles
3
Type of control element
Push button
Degree of protection (IP)
IP30
Complete device with protection unit