Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Rated voltage
600 - 600V
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
With switched-off indicator
Yes
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
No
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Integrated earth fault protection
No
Position of connection for main current circuit
Connection at separate chassis part
With under voltage release
No
Overload release current setting
640.0 - 1600A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077722R1 | E2.2V-A 1600 Ekip Touch LSI 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Rated voltage
600 .. 600V
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
With switched-off indicator
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
Complete device with protection unit
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Integrated earth fault protection
Position of connection for main current circuit
Connection at separate chassis part
With under voltage release
Overload release current setting
640.0 .. 1600A