Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of control element
Push button
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Rated voltage
600 - 600V
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Motor drive integrated
No
Overload release current setting
320.0 - 800A
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Integrated earth fault protection
Yes
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
With under voltage release
No
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077704R1 | E2.2V-A 800 Ekip G Touch LSIG 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of control element
Push button
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Rated voltage
600 .. 600V
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Motor drive integrated
Overload release current setting
320.0 .. 800A
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
With under voltage release
Degree of protection (IP)
IP30