Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
400 A
With integrated under voltage release
No
Rated voltage
600 - 600V
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
240.0 - 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
160.0 - 400A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Adjustment range undelayed short-circuit release
600.0 - 6000A
Motor drive integrated
No
Motor drive optional
Yes
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
Complete device with protection unit
Yes
Type of control element
Push button
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077694R1 | E2.2V-A 400 Ekip G Touch LSIG 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
400 A
With integrated under voltage release
Rated voltage
600 .. 600V
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
240.0 .. 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
160.0 .. 400A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Adjustment range undelayed short-circuit release
600.0 .. 6000A
Motor drive integrated
Motor drive optional
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Complete device with protection unit
Type of control element
Push button