Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
2000A
Rated voltage
600 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
800.0 - 2000A
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
3000.0 - 30000A
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
With switched-off indicator
Yes
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077617R1 | E2.2H-A 2000 Ekip G Hi-Touch LSIG 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
2000A
Rated voltage
600 .. 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
800.0 .. 2000A
Integrated earth fault protection
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
With switched-off indicator
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Complete device with protection unit
From same serie