Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2000A
Rated voltage
600 - 600V
Overload release current setting
800.0 - 2000A
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Yes
With switched-off indicator
Yes
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
With under voltage release
No
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Type of control element
Push button
Motor drive integrated
No
Complete device with protection unit
Yes
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Number of poles
3
Degree of protection (IP)
IP30
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077610R1 | E2.2H-A 2000 Ekip Dip LSIG 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2000A
Rated voltage
600 .. 600V
Overload release current setting
800.0 .. 2000A
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
With switched-off indicator
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
With under voltage release
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Type of control element
Push button
Motor drive integrated
Complete device with protection unit
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Number of poles
3
Degree of protection (IP)
IP30
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA