Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
600 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Rated permanent current Iu
2000A
Integrated earth fault protection
Yes
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Number of poles
4
Position of connection for main current circuit
Back side
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
800.0 - 2000A
Motor drive optional
Yes
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
With under voltage release
No
Motor drive integrated
No
Complete device with protection unit
Yes
Type of control element
Push button
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077566R1 | E2.2V-A 2000 Ekip Hi-Touch LSIG 4p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
600 .. 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Rated permanent current Iu
2000A
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Number of poles
4
Position of connection for main current circuit
Back side
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
800.0 .. 2000A
Motor drive optional
With switched-off indicator
DIN rail (top hat rail) mounting optional
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
With under voltage release
Motor drive integrated
Complete device with protection unit
Type of control element
Push button
From same serie
We use cookies to enhance your experience.