Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
600 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Overload release current setting
640.0 - 1600A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Yes
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Rated permanent current Iu
1600A
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive optional
Yes
Number of poles
4
Position of connection for main current circuit
Back side
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077550R1 | E2.2V-A 1600 Ekip Dip LSIG 4p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
600 .. 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Overload release current setting
640.0 .. 1600A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Rated permanent current Iu
1600A
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive optional
Number of poles
4
Position of connection for main current circuit
Back side
Complete device with protection unit
From same serie