Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
600 - 600V
Integrated earth fault protection
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
With switched-off indicator
Yes
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Number of auxiliary contacts as normally open contact
0
Number of poles
4
Complete device with protection unit
Yes
DIN rail (top hat rail) mounting optional
No
Motor drive integrated
No
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
Position of connection for main current circuit
Back side
Rated permanent current Iu
1600A
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Type of electrical connection of main circuit
Bolt connection
Degree of protection (IP)
IP30
Overload release current setting
640.0 - 1600A
Device construction
Built-in device fixed built-in technique
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077549R1 | E2.2V-A 1600 Ekip Dip LSI 4p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
600 .. 600V
Integrated earth fault protection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
With switched-off indicator
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Number of auxiliary contacts as normally open contact
0
Number of poles
4
Complete device with protection unit
DIN rail (top hat rail) mounting optional
Motor drive integrated
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
Position of connection for main current circuit
Back side
Rated permanent current Iu
1600A
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Type of electrical connection of main circuit
Bolt connection
Degree of protection (IP)
IP30
Overload release current setting
640.0 .. 1600A
Device construction
Built-in device fixed built-in technique
From same serie