Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Rated permanent current Iu
1600A
Device construction
Built-in device fixed built-in technique
Overload release current setting
640.0 - 1600A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Yes
Rated voltage
600 - 600V
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Position of connection for main current circuit
Back side
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Motor drive optional
Yes
Complete device with protection unit
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077497R1 | E2.2S-A 1600 Ekip G Hi-Touch LSIG 4p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Rated permanent current Iu
1600A
Device construction
Built-in device fixed built-in technique
Overload release current setting
640.0 .. 1600A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Rated voltage
600 .. 600V
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Position of connection for main current circuit
Back side
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Motor drive optional
Complete device with protection unit
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
From same serie