Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1200A
Adjustment range undelayed short-circuit release
1800.0 - 18000A
Overload release current setting
480.0 - 1200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Bolt connection
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Rated voltage
600 - 600V
Integrated earth fault protection
Yes
Number of poles
3
Number of auxiliary contacts as change-over contact
4
With under voltage release
No
With switched-off indicator
Yes
Device construction
Built-in device fixed built-in technique
Motor drive integrated
No
Complete device with protection unit
Yes
Position of connection for main current circuit
Back side
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
720.0 - 12000A
Degree of protection (IP)
IP30
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077370R1 | E2.2V-A 1200 Ekip Dip LSIG 3p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1200A
Adjustment range undelayed short-circuit release
1800.0 .. 18000A
Overload release current setting
480.0 .. 1200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Bolt connection
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Rated voltage
600 .. 600V
Integrated earth fault protection
Number of poles
3
Number of auxiliary contacts as change-over contact
4
With under voltage release
With switched-off indicator
Device construction
Built-in device fixed built-in technique
Motor drive integrated
Complete device with protection unit
Position of connection for main current circuit
Back side
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
720.0 .. 12000A
Degree of protection (IP)
IP30
Motor drive optional
From same serie