Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Overload release current setting
640.0 - 1600A
Rated permanent current Iu
1600A
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
600 - 600V
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Bolt connection
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Number of poles
3
Type of control element
Push button
Position of connection for main current circuit
Back side
With switched-off indicator
Yes
Degree of protection (IP)
IP30
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077280R1 | E2.2N-A 1600 Ekip Dip LSIG 3p F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Overload release current setting
640.0 .. 1600A
Rated permanent current Iu
1600A
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
600 .. 600V
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Bolt connection
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Number of poles
3
Type of control element
Push button
Position of connection for main current circuit
Back side
With switched-off indicator
Degree of protection (IP)
IP30
Motor drive optional
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Motor drive integrated
From same serie