Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
400 A
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Integrated earth fault protection
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated voltage
600 - 600V
Adjustment range undelayed short-circuit release
600.0 - 6000A
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
160.0 - 400A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
No
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077201R1 | E1.2S-A 400 Ekip Touch LI 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
400 A
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Integrated earth fault protection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated voltage
600 .. 600V
Adjustment range undelayed short-circuit release
600.0 .. 6000A
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
160.0 .. 400A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
DIN rail (top hat rail) mounting optional
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
Motor drive optional
Number of auxiliary contacts as normally open contact
0
From same serie