Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
800 A
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
320.0 - 800A
Integrated earth fault protection
No
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
600 - 600V
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
Number of poles
4
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Motor drive optional
Yes
Motor drive integrated
No
Number of auxiliary contacts as normally open contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077171R1 | E1.2N-A 800 Ekip Touch LI 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
800 A
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
320.0 .. 800A
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
600 .. 600V
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Number of poles
4
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Motor drive optional
Motor drive integrated
Number of auxiliary contacts as normally open contact
0
From same serie