Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
800 A
With integrated under voltage release
No
Rated voltage
600 - 600V
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Motor drive optional
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Overload release current setting
320.0 - 800A
Motor drive integrated
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077135R1 | E1.2S-A 800 Ekip Hi-Touch LSI 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
800 A
With integrated under voltage release
Rated voltage
600 .. 600V
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Motor drive optional
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Overload release current setting
320.0 .. 800A
Motor drive integrated
Complete device with protection unit
Degree of protection (IP)
IP30
From same serie