Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
800 A
With integrated under voltage release
No
Overload release current setting
320.0 - 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Rated voltage
600 - 600V
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Motor drive optional
Yes
Motor drive integrated
No
With switched-off indicator
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Type of control element
Push button
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077129R1 | E1.2S-A 800 Ekip Dip LSI 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
800 A
With integrated under voltage release
Overload release current setting
320.0 .. 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Rated voltage
600 .. 600V
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Motor drive optional
Motor drive integrated
With switched-off indicator
Degree of protection (IP)
IP30
Complete device with protection unit
Type of control element
Push button
From same serie
We use cookies to enhance your experience.