Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Integrated earth fault protection
No
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
1200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
600 - 600V
Number of poles
3
Overload release current setting
480.0 - 1200A
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Adjustment range undelayed short-circuit release
1800.0 - 18000A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077101R1 | E1.2N-A 1200 Ekip Touch LI 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
1200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Type of electrical connection of main circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
600 .. 600V
Number of poles
3
Overload release current setting
480.0 .. 1200A
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Adjustment range undelayed short-circuit release
1800.0 .. 18000A