

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
320.0 - 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Rated voltage
600 - 600V
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Position of connection for main current circuit
Connection at separate chassis part
With under voltage release
No
Motor drive integrated
No
Motor drive optional
Yes
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Complete device with protection unit
Yes
Rated permanent current Iu
800A
Degree of protection (IP)
IP30
Number of poles
3
With switched-off indicator
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA077070R1 | E1.2B-A 800 Ekip Dip LSIG 3p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
320.0 .. 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Rated voltage
600 .. 600V
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Position of connection for main current circuit
Connection at separate chassis part
With under voltage release
Motor drive integrated
Motor drive optional
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Complete device with protection unit
Rated permanent current Iu
800A
Degree of protection (IP)
IP30
Number of poles
3
With switched-off indicator
From same serie
We use cookies to enhance your experience.