Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
60.0 - 150A
Rated permanent current Iu
250A
Adjustment range short-term delayed short-circuit release
150 - 1500A
Rated voltage
240 - 600V
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Yes
DIN rail (top hat rail) mounting optional
Yes
Device construction
Built-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
35kA
Type of control element
Toggle
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Front side
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
Number of poles
3
With integrated under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
Degree of protection (IP)
IP20
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
150 - 1500A
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA075493R1 | XT4S 250 Ekip LSIG In=150A 3p F F UL/CSA

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
60.0 .. 150A
Rated permanent current Iu
250A
Adjustment range short-term delayed short-circuit release
150 .. 1500A
Rated voltage
240 .. 600V
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Device construction
Built-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
35kA
Type of control element
Toggle
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Front side
Motor drive integrated
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
Number of poles
3
With integrated under voltage release
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
Degree of protection (IP)
IP20
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
150 .. 1500A
Complete device with protection unit
From same serie