Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
240 - 600V
Rated permanent current Iu
250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25kA
Overload release current setting
100.0 - 250A
Adjustment range short-term delayed short-circuit release
250 - 2500A
Adjustment range undelayed short-circuit release
250 - 2500A
Integrated earth fault protection
Yes
Number of auxiliary contacts as change-over contact
0
Suitable for DIN rail (top hat rail) mounting
No
With integrated under voltage release
No
Type of electrical connection of main circuit
Bolt connection
Number of poles
3
With switched-off indicator
No
DIN rail (top hat rail) mounting optional
Yes
Device construction
Built-in device fixed built-in technique
Motor drive optional
Yes
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Front side
Degree of protection (IP)
IP20
Type of control element
Toggle
Complete device with protection unit
Yes
Motor drive integrated
No
Number of auxiliary contacts as normally open contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA075483R1 | XT4N 250 Ekip LSIG In=250A 3p F F UL/CSA

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
240 .. 600V
Rated permanent current Iu
250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25kA
Overload release current setting
100.0 .. 250A
Adjustment range short-term delayed short-circuit release
250 .. 2500A
Adjustment range undelayed short-circuit release
250 .. 2500A
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
0
Suitable for DIN rail (top hat rail) mounting
With integrated under voltage release
Type of electrical connection of main circuit
Bolt connection
Number of poles
3
With switched-off indicator
DIN rail (top hat rail) mounting optional
Device construction
Built-in device fixed built-in technique
Motor drive optional
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Front side
Degree of protection (IP)
IP20
Type of control element
Toggle
Complete device with protection unit
Motor drive integrated
Number of auxiliary contacts as normally open contact
0