Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release
225 - 2250A
Integrated earth fault protection
No
Rated voltage
240 - 600V
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Yes
Type of control element
Toggle
Complete device with protection unit
Yes
Motor drive integrated
No
Adjustment range undelayed short-circuit release
225 - 2250A
With integrated under voltage release
No
Number of poles
4
Rated permanent current Iu
250A
Position of connection for main current circuit
Front side
With switched-off indicator
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Degree of protection (IP)
IP20
Overload release current setting
90.0 - 225A
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA075416R1 | XT4V 250 Ekip LS/I In=225A 4p F F UL/CSA

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release
225 .. 2250A
Integrated earth fault protection
Rated voltage
240 .. 600V
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Type of control element
Toggle
Complete device with protection unit
Motor drive integrated
Adjustment range undelayed short-circuit release
225 .. 2250A
With integrated under voltage release
Number of poles
4
Rated permanent current Iu
250A
Position of connection for main current circuit
Front side
With switched-off indicator
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Degree of protection (IP)
IP20
Overload release current setting
90.0 .. 225A
Motor drive optional
Number of auxiliary contacts as normally open contact
0
From same serie