Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
240 - 600V
Overload release current setting
90.0 - 225A
Rated permanent current Iu
250A
Adjustment range short-term delayed short-circuit release
225 - 2250A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
Yes
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
225 - 2250A
With switched-off indicator
No
With integrated under voltage release
No
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Motor drive optional
Yes
Position of connection for main current circuit
Front side
Complete device with protection unit
Yes
Degree of protection (IP)
IP20
Type of control element
Toggle
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA075392R1 | XT4L 250 Ekip LS/I In=225A 4p F F UL/CSA

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
240 .. 600V
Overload release current setting
90.0 .. 225A
Rated permanent current Iu
250A
Adjustment range short-term delayed short-circuit release
225 .. 2250A
Integrated earth fault protection
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
225 .. 2250A
With switched-off indicator
With integrated under voltage release
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Motor drive optional
Position of connection for main current circuit
Front side
Complete device with protection unit
Degree of protection (IP)
IP20
Type of control element
Toggle
From same serie