Aleta.hr
Main Product Image

1SDA074724R1 | XT1H 125 MCP In=3 3p F F UL/CSA

Code: 1983049

ManufacturerRAZNO
Catalog number1SDA074724R1
Type
EAN code8015644787011

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

- - -A

Adjustment range short-term delayed short-circuit release

- - -A

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

No

Suitable for DIN rail (top hat rail) mounting

No

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

12 - 33A

Rated voltage

240 - 347V

Rated permanent current Iu

125A

DIN rail (top hat rail) mounting optional

Yes

Integrated earth fault protection

No

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

No

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Number of poles

3

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

No

Motor drive optional

Yes

Type of control element

Toggle

Complete device with protection unit

Yes

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

1SDA074724R1 | XT1H 125 MCP In=3 3p F F UL/CSA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

12 .. 33A

Rated voltage

240 .. 347V

Rated permanent current Iu

125A

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Number of poles

3

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Motor drive optional

Type of control element

Toggle

Complete device with protection unit

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.