Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- ABB
Technical specifications
Version as main switch
Yes
Version as reversing switch
No
Version as safety switch
No
Max. rated operation voltage Ue AC
1000V
Rated permanent current at AC-21, 400 V
-A
Version as maintenance-/service switch
Yes
Number of switches
1
Rated operation power at AC-3, 400 V
-kW
Switching power at 400 V
220kW
Rated operating voltage
1000 - 1000V
Rated operation power at AC-23, 400 V
220kW
Version as emergency stop installation
No
Rated permanent current at AC-23, 400 V
400A
Rated short-time withstand current lcw
15kA
Rated permanent current Iu
400A
Conditioned rated short-circuit current Iq
-kA
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Voltage release optional
No
Motor drive integrated
No
Motor drive optional
No
Suitable for intermediate mounting
No
Type of control element
Other
Device construction
Complete device in housing
Type of electrical connection of main circuit
Bolt connection
Suitable for floor mounting
No
Suitable for front mounting 4-hole
No
Suitable for distribution board installation
Yes
Degree of protection (NEMA)
Other
Suitable for front mounting centre
No
With pre-assembled cabling
No
Width
226mm
Interlockable
No
Degree of protection (IP), front side
IP00
Height
220mm
Width in number of modular spacings
-
Depth
105mm
From same serie
1SCA022754R6450 | OT400U12

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- ABB
Technical specifications
Version as main switch
Version as reversing switch
Version as safety switch
Max. rated operation voltage Ue AC
1000V
Rated permanent current at AC-21, 400 V
-A
Version as maintenance-/service switch
Number of switches
1
Rated operation power at AC-3, 400 V
-kW
Switching power at 400 V
220kW
Rated operating voltage
1000 .. 1000V
Rated operation power at AC-23, 400 V
220kW
Version as emergency stop installation
Rated permanent current at AC-23, 400 V
400A
Rated short-time withstand current lcw
15kA
Rated permanent current Iu
400A
Conditioned rated short-circuit current Iq
-kA
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Voltage release optional
Motor drive integrated
Motor drive optional
Suitable for intermediate mounting
Type of control element
Other
Device construction
Complete device in housing
Type of electrical connection of main circuit
Bolt connection
Suitable for floor mounting
Suitable for front mounting 4-hole
Suitable for distribution board installation
Degree of protection (NEMA)
Other
Suitable for front mounting centre
With pre-assembled cabling
Width
226mm
Interlockable
Degree of protection (IP), front side
IP00
Height
220mm
Width in number of modular spacings
-
Depth
105mm
From same serie