Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- ABB
Technical specifications
Version as maintenance-/service switch
Yes
Number of switches
1
Version as reversing switch
No
Version as safety switch
No
Version as emergency stop installation
No
Max. rated operation voltage Ue AC
1000V
Rated operating voltage
1000 - 1000V
Rated permanent current at AC-23, 400 V
400A
Rated permanent current at AC-21, 400 V
-A
Rated permanent current Iu
400A
Rated short-time withstand current lcw
15kA
Rated operation power at AC-3, 400 V
-kW
Rated operation power at AC-23, 400 V
220kW
Conditioned rated short-circuit current Iq
-kA
Switching power at 400 V
220kW
Version as main switch
Yes
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Motor drive integrated
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Voltage release optional
No
Suitable for front mounting 4-hole
No
Device construction
Complete device in housing
Suitable for floor mounting
No
Suitable for front mounting centre
No
Suitable for distribution board installation
Yes
Type of control element
Other
Suitable for intermediate mounting
No
Motor drive optional
No
Interlockable
No
Type of electrical connection of main circuit
Bolt connection
With pre-assembled cabling
No
Degree of protection (IP), front side
IP00
Width
221mm
Degree of protection (NEMA)
Other
Height
220mm
Depth
105mm
Width in number of modular spacings
-
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SCA022747R6490 | OT400U03

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- ABB
Technical specifications
Version as maintenance-/service switch
Number of switches
1
Version as reversing switch
Version as safety switch
Version as emergency stop installation
Max. rated operation voltage Ue AC
1000V
Rated operating voltage
1000 .. 1000V
Rated permanent current at AC-23, 400 V
400A
Rated permanent current at AC-21, 400 V
-A
Rated permanent current Iu
400A
Rated short-time withstand current lcw
15kA
Rated operation power at AC-3, 400 V
-kW
Rated operation power at AC-23, 400 V
220kW
Conditioned rated short-circuit current Iq
-kA
Switching power at 400 V
220kW
Version as main switch
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Motor drive integrated
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Voltage release optional
Suitable for front mounting 4-hole
Device construction
Complete device in housing
Suitable for floor mounting
Suitable for front mounting centre
Suitable for distribution board installation
Type of control element
Other
Suitable for intermediate mounting
Motor drive optional
Interlockable
Type of electrical connection of main circuit
Bolt connection
With pre-assembled cabling
Degree of protection (IP), front side
IP00
Width
221mm
Degree of protection (NEMA)
Other
Height
220mm
Depth
105mm
Width in number of modular spacings
-
From same serie
We use cookies to enhance your experience.